The Toughsonic Chem Ultrasonic Sensors are the more rugged version of the Toughsonic General purpose line, suitable for use in diesel fuels and chemical level applications in closed or open tanks. These durable, compact ultrasonic level sensors measure a wide variety of liquids from diesel fuel in rail locomotives to chemcial tanks in the paper and food processing industries. The Toughsonic Chem 10 sensor provides non-contact measurements at distances up to 10 feet (3m), with an optimum range of 4 to 80 inches (100mm to 2m). Heavy duty electronics are epoxy potted into a polyvinylidene fluroride (PVDF) housing that physically isolates the transducer and electronics from chemicals and can withstand exposure to both acids and bases.
The Toughsonic Chem Ultrasonic Sensors are the more rugged version of the Toughsonic General purpose line, suitable for use in diesel fuels and chemical level applications in closed or open tanks. These durable, compact ultrasonic level sensors measure a wide variety of liquids from diesel fuel in rail locomotives to chemcial tanks in the paper and food processing industries. The Toughsonic Chem 10 sensor provides non-contact measurements at distances up to 10 feet (3m), with an optimum range of 4 to 80 inches (100mm to 2m). Heavy duty electronics are epoxy potted into a polyvinylidene fluroride (PVDF) housing that physically isolates the transducer and electronics from chemicals and can withstand exposure to both acids and bases. The Chem sensors are used both indoors and out, and in some of the harshest factory environments. They are also suitable in liquid level applications where chemical resistance is not a neccesity.
Our WhitmanVIEW Sensor Software (DOWNLOAD) is included at no extra charge, runs on a windows PC and connects to sensors via a serial data port. Our Setup Kits provide everything needed to connect through a USB port, including power supply, sensor-PC interface and cables. WhitmanVIEW is not required but adds powerful configuration, test and management capability.
For more information, visit our technical resources page.
Is OEM Replacement Part? | No |
---|---|
Max Range | 10 Feet (3 meters) |
Optimum Range | 4 inches - 80 inches (102 millimeters - 2 meters) |
Temperature Range | -40°F to 158°F (-40°C to 70°C) |
Humidity | 0 to 100% operating |
Protection | NEMA-4X, NEMA 6P, IP68 |
Transducer | Ruggedized piezolelectric |
Compensation | Temperature compensated |
Resolution | Digital: 0.0034 inches (0.086 millimeters), Analog: 4099 steps (0-10 VDC), 3279 steps (4-20 mA) |
Repeatability | Nominal 0.2% of range @ constant temperature. Affected by target, distance, environment |
Update Rate | 5 Hz (100 ms), Software adjustable; affected by software filter selections |
Mounting Type | 1.5 inch NPT/BSP Universal lower thread. 1 Inch NPT upper thread |
Attached Cable | 6.5 Feet (2 Meters) - Standard. More options available |
Voltage Output | 0-10, 0-5 VDC or customized by software; 10 mA max. |
Current Loop | Current sourcing 4-20 mA or software customized, max loop 450Ω |
Current Loop 2 | Current sinking 4-20 mA or software customized, max loop 450Ω |
Sinking Switch | 150 mA max @ 40 VDC max, teachable set point & polarity, fault indication |
Sourcing Switch | 150 mA max @ input voltage, teachable set point & polarity, fault indication |
RS-232, RS-485 | RS-485 is standard |
Protocols | Modbus protocol, 9600-115200 baud (selectable), 8 data bits, 1 stop, no parity |
SYNC Feature | Permits up to 32 sensors to operate in close proximity without interference |