P119G Zinc Diecast Body Pressure Switch

Product Overview

Product Datasheet

P119G
[]

The P119G Zinc Diecast Body Pressure Switches are the inexpensive version of the P117G and recommended for indoor OEM use. The compact nature of these switches make them ideal for tight spaces. 

  • Set Point Range: 0.80 to 500 PSIG
  • Max System Pressure: 150% of sensor capacity
  • Temperature range: -65°F to +225°F (-54°C to +107°C)
Custom / 2 - 4 Weeks
$89.50
$89.50

The Whitman Controls P119G Zinc Diecast Body Pressure Switches are the inexpensive version of the P117G and recommended for indoor OEM use. It is used as a pressure limit switch on X-Ray tube and Cat Scan Tubes as well as a safety switch in numerous applications. The compact nature of these switches make them ideal for tight spaces. They are available with a cast in ¼” NPT fitting as an option. There are also several electrical interface options available.

 Key Features:

  • Zinc Diecast Body
  • Set point options: Factory set, field adjustable, or a combination
  • Extensive operating temperature range
  • Wide range of electrical interfaces available
  • SPDT or SPST availability

 Specifications:

  • Set point range: 0.80 to 500 PSIG
  • Max System pressure: 150% of sensor capacity
  • Temperature range: -65°F to +225°F (-54°C to +107°C)
  • Amps: 5 Amps Max
  • Sensor Element: Capsule
  • Weight: 2.0 oz (varies with electrical interface selection)
  • Cycling: 3H/5H - Not to exceed 60 CPM, 10H/25H/50H - Not to exceed 20 CPM
  • Wetted Parts:
    Capsule: 17-7 PH
    Seal: Loctite #271
    Body with Fitting: Round Body - Zamac 3 / Chromate finish, Hex Body - ZA8, chromate finish
    Body: Anodized aluminum
    Standard Thread: ⅛-27 NPT male, Optional Threads: ¼-18 NPT male (Hex body only)
More Information
Switch ApplicationZinc Alloy P119 (1-500psig)
Is OEM Replacement Part?No
Switch AvailabilityCustom / 2 - 4 Weeks
StockIn Stock
Set Point Pressure Range1 to 30
Circuit TypeSPST
Set Point Options SPST Customer Set
Maximum Amperage and Voltage0.1 Amp 125 VAC Gold Plate
Electrical InterfaceL - 12" Leads - Insulated Base
Maximum System Pressure30 PSIG
Fitting1/8" NPT Male
Corrosive MediaNo
Wet/Dry/SubmergedStandard (Dry use)
Wetted MaterialsZinc, SS & Loctite
Additional OptionsMany Options are Available. If it's not here, call us.
Standard Fitting Size1/8"NPT
Shipping Weight Ounces5 ozs